- APPS
- Shop Floor Control - Maintenance 19.0
| Lines of Code | 1216 |
| Technical name | viin_mrp_workorder_maintenance |
| License | OPL-1 |
| Website | https://viindoo.com/apps/modules/19.0/viin_mrp_workorder_maintenance |
| Read description for | v 18.0 |
| Required Apps | Manufacturing (mrp) Discuss (mail) Employees (hr) Inventory (stock) Maintenance (maintenance) |
| Included Dependencies | Shop Floor Control Maintenance - MRP Viindoo Manufacturing Web Gantt |
Machine down: the station stops and a technician is called in the same tap
For manufacturers who run their work orders on a tablet at the machine
Report a machine breakdown from the Shop Floor tablet: one tap stops the work center and calls a technician, with no typing.
Community Edition, Viindoo Cloud · OPL-1 · English, Vietnamese
Extends Shop Floor Control, the tablet screen operators work on.
Extends Maintenance - MRP, the requests, machines and breakdown reasons it uses, with MTBF and MTTR per machine.
What changes for your team
A breakdown reported at the machine, in two taps
The operator stops the job, then looks for someone or a desktop to report the failure. The request arrives late, without the order or the exact machine.
→ The operator taps Equipment failure - call maintenance, then what is wrong. The station stops and the request exists at that moment, titled from the reason and the machine, with the order attached. A photo of the fault can follow.
One call per breakdown, and everyone at the station knows the next step
A second operator, unsure whether help is coming, raises a second request for the same failure.
→ A second tap, or a second tablet at the same station, joins the open request. The tablet names who called the technician and when, and where Restart station is if production must run before the repair.
Back to work on a decision, and on the record
Whether a machine may run again is settled by word of mouth, and nobody knows who restarted it.
→ A repair closed in maintenance puts the station back to work. A request closed without a repair is shown on the tablet; any Manufacturing user then restarts the station after one question, and the restart is listed and noted on the request.
Features
Report at the machine
- ✓ One tap stops the station, calls a technician and starts the downtime
- ✓ The machine comes from the station; a tap list when it has several
- ✓ Tap what is wrong; the stop reason and request title follow
- ✓ A photo of the fault goes into the request
- ✓ Call maintenance for a machine that keeps running, without stopping
One call per breakdown
- ✓ A second tap or tablet joins the request already raised
- ✓ Every tablet at the station shows who called the technician, and when
- ✓ A station already stopped for another reason switches to the breakdown
- ✓ A failure cannot be logged as a plain stop without a technician
Back to work
- ✓ The tablet says what the stop waits for and where Restart station is
- ✓ A repair closed in maintenance puts the station back to work
- ✓ A request closed without a repair is shown on the tablet
- ✓ Any Manufacturing user restarts a stopped station after one question
- ✓ The request holding the station receives an internal note on restart
Built for daily use
- ✓ Every report, call and restart is listed with who recorded it
- ✓ A tap retried on a weak connection never raises a second request
- ✓ Operators see their own entries; Manufacturing administrators see all
- ✓ The request carries the manufacturing order, work order, reason and stop
Ready on day one
Installs by itself
It is added as soon as Shop Floor Control and Maintenance - MRP are both installed. It has no menu or settings of its own.
Breakdown reasons
Machine Jammed, Overheating, Unusual Noise and Broken Part are ready to tap; the maintenance manager edits the list.
Closing stages
Repaired returns the machine to service, Scrap keeps the station stopped; the maintenance manager decides per stage.
Set up first
Link each machine to its work center and technician, and keep a maintenance team for the company.
Before you decide
What if the station was already stopped for another reason?
It stays stopped and its stop reason becomes the breakdown, so the downtime is neither split nor lost.
What if the connection drops during a report?
The operator taps again once it is back. A retried report is applied once and never raises a second request.
Who sees what?
Operators with the Manufacturing / User right report, follow their calls, restart a station and see the Shop Floor Entries they recorded. Manufacturing administrators see all entries. The technician is the one named on the machine.
Can a failure be logged without calling a technician?
No. The breakdown reasons are kept off the plain stop list, so a failure reported on the tablet always comes with a maintenance request.
Where does the data go, and where do I read the downtime?
Into the standard maintenance requests and work center records of your own database; the module calls no outside service. Every report, call and restart is listed in Shop Floor Entries, and Maintenance - MRP tracks MTBF and MTTR per machine.
Try it, then ask us
The video above shows it at work. The Documentation tab covers setup and daily use role by role, and the Live Preview of this listing lets you try it first.
Pre-sales & partnership
viindoo.com/contactusTechnical support
viindoo.com/ticketShop Floor Control - Maintenance
Who this guide is for. Machine operators and shift leads who work on the Shop Floor tablet (access rights Manufacturing / User and Manufacturing / Administrator), maintenance technicians who close the requests, and the administrator who gives people their access rights.
Note
Extends viin_mrp_workorder - see its documentation.
Note
Extends viin_mrp_maintenance - see its documentation.
Shop Floor Control - Maintenance lets a machine operator report a breakdown on the tablet, at the machine, instead of walking to a desktop. One tap stops the station and calls a technician. Nothing has to be typed: the machine and the problem are picked from tap lists, the title of the request is written for you, and a photo of the fault can be added from the tablet camera. The downtime is timed from that tap.
The screenshots show the demo company. Marc Demo is the machine operator. Mitchell Admin is the second person at the station, the technician who closes the requests and the shift lead. The station Assembly 1 has two machines, Crosscut Saw: 8 ppi. and Scrub Plane. Drill 1 has one machine, Drill Machine.
Overview
A breakdown goes through three stages.
- Report. The operator taps Stop machine, then Equipment failure - call maintenance, picks the machine and what is wrong. The station stops and a maintenance request is created at the same moment. The request is handed to the technician.
- Repair and close. The technician repairs the machine and closes the request in a stage. A closing stage that returns the machine to service puts the station back to work. Any other closing stage, such as Scrap, leaves it stopped.
- Back to work. After Scrap, someone on the shop floor restarts the station once production may run again. The restart is recorded and the request receives a note.
| Role | What they do | Access right to assign |
|---|---|---|
| Machine operator | Reports a breakdown, calls maintenance for a machine that keeps running, follows the call and restarts the station when the machine was not repaired. | Manufacturing / User |
| Maintenance technician | Repairs the machine and closes the request in the stage Repaired or Scrap. | Internal user, named in Responsible of the request |
| Shift lead | Checks every breakdown and call in Shop Floor Entries. | Manufacturing / Administrator |
| Administrator | Gives each person their access right. The module installs itself. | Role / Administrator |
Setup (for the Administrator)
Installation
The module installs itself as soon as both Shop Floor Control and Maintenance - MRP are installed. If it is not installed yet:
- Open Apps.
- Search for Shop Floor Control - Maintenance.
- Click Install.
The module adds no menu of its own. Everything happens on the Shop Floor screen, in the Maintenance Requests list and in Shop Floor Entries.
Access rights
- Give each operator the access right Manufacturing / User. Operators see the Shop Floor app, report breakdowns, follow their calls and restart a stopped station.
- Give each shift lead the access right Manufacturing / Administrator. Shift leads see every line of Shop Floor Entries. An operator sees the lines they recorded.
- The technician is any internal user. A request names the technician in Responsible, taken from the Technician of the machine.
- Link the user of each operator to an employee: on the employee, open the Settings tab and fill User. Without this link the tablet refuses to start a job. See the Shop Floor Control guide.
Machines, reasons and closing stages
These are set in the Maintenance - MRP guide, which describes them in detail.
- Each machine names the work center it belongs to, its Technician and its Maintenance Team: Maintenance ‣ Equipment ‣ Machines & Tools. With one machine on the work center the tablet skips the question Which machine?. With no machine, the request is sent without one and the technician finds the machine on arrival.
- At least one maintenance team must work for the company of the work order, otherwise the tablet refuses the report before anything is stopped.
- The choices under What is wrong? are the request reasons: Maintenance ‣ Configuration ‣ Request Reasons. Four are ready to use: Machine Jammed, Overheating, Unusual Noise and Broken Part. Each one stops the station for the stop reason Equipment Failure.
- Equipment Failure is not offered among the plain reasons of the stop screen, so nobody can stop a machine for a failure without calling a technician.
- The option Returns Machine to Service of a maintenance stage decides which closing stage puts the station back to work. Repaired does, Scrap does not: Maintenance ‣ Configuration ‣ Maintenance Stages.
Usage
Machine operator: report a breakdown and follow the call
Report a breakdown
On the home menu, tap Shop Floor and tap your station under My stations. On the card of your job, tap Open & start for a job that has not started, or Resume operation for a paused job: the operation opens and the clock runs. Tap Close, then the tab Running: the card carries the badge Running and its button reads Continue operation.
Tap Continue operation. The operation screen opens. Tap Stop machine.
The screen asks "What's happening?". The plain reasons for a stop are under Other reason. Below them, the red button Equipment failure - call maintenance reads "Machine broken? This stops the station and calls a technician."
Tap Equipment failure - call maintenance. If the station has several machines, the question Which machine? appears. Tap the machine that broke, for example Crosscut Saw: 8 ppi.. With a single machine the tablet skips this question and tells you which machine is attached to the request.
Under What is wrong?, tap the problem, for example Machine Jammed. This tap is the report: there is no confirmation step and nothing to type. Tap Cancel instead if you tapped by mistake.
The panel Waiting for maintenance confirms "Breakdown reported - the station is stopped and a technician has been called." and shows the title of the request, written from the reason and the machine. The bottom of the screen reads Station stopped: Equipment Failure, next to the button Restart station.
Optional: tap Take photo, photograph the fault with the tablet camera and confirm. The tablet says "Photo added to the request." and the technician sees the photo in the request. If the photo cannot be added, the tablet tells you and the report itself is kept.
Tap Back to return to the operation screen. The red band Station stopped: Equipment Failure names who called the technician, at what time and for which request, and says where Restart station is: in the job card menu and on the operation screen. The button Stop machine then reads Station stopped - view details.
While the station is stopped, the operation cannot be paused or finished and no output can be recorded until the station is back at work.
Follow the call and join a colleague's call
One call is enough for a station. When a technician has already been called, a second tap does not create a second request.
Open your job on the stopped station and tap Station stopped - view details. The panel Waiting for maintenance names who called the technician, at what time and for which request, and says where Restart station is. The time is shown in your own time zone.
A colleague at the same station sees the same panel on their own tablet. If their tablet was already on the stop screen when the first operator reported, Equipment failure - call maintenance is still shown. Tapping it, the machine and the problem joins the call that is already open: the panel names the first caller, no new request is created and no Take photo button is offered, because the request was not created by this tablet.
A tap that is repeated after a lost connection never creates a second request either. If the station was already stopped for another reason, the breakdown takes over: the station stays stopped, its stop reason becomes Equipment Failure and the downtime from the first stop is kept.
The screen shows what it knew when you opened it. Tap Refresh on the job board to see the latest state of every job.
Call maintenance for a machine that keeps running
Use this when the machine still works but needs servicing, for example it rattles. Production does not stop.
Open your job. While the station is running, the operation screen offers Call maintenance (machine keeps running), below Materials. Tap it. If the station has several machines, tap the machine first.
A green message replaces the button: "Maintenance request sent - the technician will service the machine without stopping production." The job keeps running and the station is not stopped. If the station has no machine, the message adds "No machine is declared for this station - the request was created with no machine attached."
Optional: tap Take photo. The tablet says "Photo added to the request."
The technician finds the request in Maintenance ‣ Maintenance ‣ Maintenance Requests, titled automatically (here Maintenance request - Drill Machine/SP/224/00000000) with the manufacturing order and the work order filled in. It does not hold the station.
Restart the station after the machine was scrapped
When the technician closes the request in the stage Scrap, the station stays stopped. Any Manufacturing user at the station decides when production may run again.
Open the job of the stopped station. On the job board, the tab Station stopped lists the jobs of the station and each card carries the badge Station stopped. Tap Open operation, then Station stopped - view details.
The red notice Machine not repaired - request closed says "Maintenance closed request ... at stage Scrap without repairing the machine. Once production may run again, restart the station with Restart station, found in the job card menu and on the operation screen."
Decide what to do with the machine, then tap Restart station: on this screen, on the operation screen, or in the menu of the job card (the three dots on the card). The question "Restart this station?" appears because the restart releases the station for everyone. Keep it stopped leaves things as they were.
Tap Yes, restart. The station runs again. Close the screen with Back and Close, then tap Refresh on the job board: the stopped band is gone and the jobs, listed under the tab Ready, show Operation paused. Each operator taps Resume operation to continue.
The request receives an internal note: "Work center Assembly 1 was restarted from the shop floor before this request returned the machine to service." It notifies nobody; the technician sees that production ran again. A restart while the request is still open leaves the same note.
Maintenance technician: repair and close the request
Close the request: the station runs again
Open Maintenance ‣ Maintenance ‣ Maintenance Requests and switch to the list. The requests that name you in Responsible are yours; a Maintenance / Equipment Manager opens every request.
Open the breakdown request, here Machine Jammed - Crosscut Saw: 8 ppi./SP/222/00000000. The form shows the machine in Equipment, the team, Responsible, the Manufacturing Order, the Work Order, the Reason and the Work Center Stop, which reads "Assembly 1 - Equipment Failure". The photo of the operator is in the chatter beside the form.
Repair the machine, then click Repaired in the status bar. The chatter logs "Work center Assembly 1 is back in service." The downtime ends at that moment.
On the tablets the red band is gone once the screen is refreshed. The jobs, listed under the tab Ready, show Operation paused: each operator taps Resume operation to carry on.
If the machine cannot be repaired, close the request in the stage Scrap instead. The chatter says "Work center Assembly 1 stays stopped: this stage does not return the machine to service." The station then stays stopped until someone restarts it, as described in "Restart the station after the machine was scrapped".
Shift lead: check every call
Check every breakdown and call
Every breakdown tap, every maintenance call and every restart is recorded in Manufacturing ‣ Reporting ‣ Shop Floor Entries, with the kind Breakdown, Maintenance Request or Restart, the work order and who recorded it. A tap that returned the call already made by a colleague is listed too, so you can see who tapped. A shift lead sees every line; an operator sees their own.
The list opens with the filters Production and Done: remove them to see every kind. Switch on the columns Work Order, Kind and Recorded By with the column selector at the right end of the header.
Troubleshooting
- I do not see "Equipment failure - call maintenance". The reason of a breakdown is not a plain stop reason. Tap Stop machine on the operation screen. If you still do not see the button, a request already holds the station: you see Waiting for maintenance instead.
- "No breakdown reasons are configured yet. Ask the maintenance manager to set them up." There is no active request reason. A maintenance manager adds them in Maintenance ‣ Configuration ‣ Request Reasons.
- "No maintenance team works for company ..., so the maintenance request cannot be sent." Ask the maintenance manager to create a maintenance team for the company, then tap again. Nothing was stopped.
- I do not see "Call maintenance (machine keeps running)". It is offered only while the station is running. When the station is stopped, use the call that is already open.
- The request was created without a machine. The work center has no machine. Link the machines to the work center, see "Machines, reasons and closing stages".
- "Your user is not linked to an employee." Ask a manager to link your user to an employee before you start or resume a job from the tablet.
- Maintenance closed the request but the station is still stopped. The request was closed in a stage that does not return the machine to service, for example Scrap. Restart the station, see "Restart the station after the machine was scrapped".
- The station is repaired but my job still looks stopped. Tap Refresh on the job board, then tap Resume operation.
- My connection dropped while I was reporting. Tap again when the connection is back. A report that is retried is applied once, never twice.
FAQ
Do operators need to type?
No. The machine and the problem are tiles, and the title of the request is written automatically. Only a free description of a stop uses the keyboard, and it is optional.
Can I stop a machine for a failure without calling a technician?
No. Equipment Failure is not offered among the plain stop reasons.
What if the station was already stopped for another reason?
The breakdown takes over: the station stays stopped, its stop reason becomes Equipment Failure and the downtime is not lost.
Does a second tap create a second request?
No. The second tap shows who called the technician and when.
Who can restart a stopped station?
Any Manufacturing user, with Restart station on the operation screen or in the menu of the job card. Every restart is recorded in Shop Floor Entries and leaves a note on the request that was holding the station.
Where do I see who reported what?
In Manufacturing ‣ Reporting ‣ Shop Floor Entries.
This software and associated files (the "Software") may only be used (executed, modified, executed after modifications) if you have purchased a valid license from the authors, typically via Odoo Apps, or if you have received a written agreement from the authors of the Software (see the COPYRIGHT file).
You may develop Odoo modules that use the Software as a library (typically by depending on it, importing it and using its resources), but without copying any source code or material from the Software. You may distribute those modules under the license of your choice, provided that this license is compatible with the terms of the Odoo Proprietary License (For example: LGPL, MIT, or proprietary licenses similar to this one).
It is forbidden to publish, distribute, sublicense, or sell copies of the Software or modified copies of the Software.
The above copyright notice and this permission notice must be included in all copies or substantial portions of the Software.
THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.